- Loosen the fasteners securing the valve cover nuts, then remove the nuts, the cover, and the gasket.
- Remove the sleeve and clamps from the valve.
- Fit a dial gauge as shown in the figure, so that its plunger rests on the flat part of the valve.
- Set the dial gauge to zero.
- Apply pressure to the actuator.
- Once the gauge reads the displacement specified in the tables (see the exploded view in the Garrett T-Series catalog), record the pressure and check that it falls within the required range.
- Release the pressure and check that the gauge returns to zero.
- If the pressure is incorrect, the valve must be replaced.
Running an engine with an incorrectly calibrated turbo actuator can cause a loss of power or serious engine damage.