Technical data
| Part / dimension | lbf·in | N·m | ||
|---|---|---|---|---|
| min. | max. | min. | max. | |
| Boltsturbine housing | 324,0 | 372,0 | 36,6 | 42,0 |
| backplate | 330,0 | 360,0 | 37,3 | 40,7 |
| Shaft nut1st - Tighten to | 125,0 | 150,0 | 14,1 | 17,0 |
| 2nd - Loosen the nut | — | — | — | — |
| 3rd - Retorque to | 35,0 | 55,0 | 4,0 | 6,2 |
| 4th - Plus additional turn of 130º-145º | — | — | — | — |
| V clampcompressor housing | 110,0 | 130,0 | 12,4 | 14,7 |
Manufacturer reference values. If in doubt, check the service manual or ask us.