Torques |
||||
|---|---|---|---|---|
| Part | Pounds per Inch | Newtons per meter | ||
| Min. | Max. | Min. | Max. | |
Bolts |
||||
| turbine housing | 324,0 | 372,0 | 36,6 | 42,0 |
| backplate | 330,0 | 360,0 | 37,3 | 40,7 |
Shaft nut |
||||
| 1st - Tighten to | 125,0 | 150,0 | 14,1 | 17,0 |
| 2nd - Loosen the nut | ||||
| 3rd - Retorque to | 35,0 | 55,0 | 4,0 | 6,2 |
| 4th - Plus additional turn of 130º-145º | ||||
V clamp |
||||
| compressor housing | 110,0 | 130,0 | 12,4 | 14,7 |